Optimization Biogas Utilization
WWTP Emmen, The Netherlands
Scope
- Design & Contsruct (UAV-gc)
- CHP including exhaust gas treatment
- Biogas pre-treatment
- Energy distribution
- 1 + 5 year 24/7 Service and Maintenance
Technical Data
- CHP system for 500kWe and 550kWth
- Biogas pre-treatment 250Nm3/hour
- DeNOx system < 340 mg NOx/Nm3
- Main Distribution board 1600A
System & Technologies
- Senergie 500CHP unit with Liebherr 9512 gas motor
- Biological desulphurization 250Nm3/hour 1000 ppm - 100 ppm H2S
- Gas dryer and pre - heating
- Gas booster
- Activated Carbon Filter for silxane removal and rest desulphurization (dual function goal)
- Autonomous process control system and local MMI
- Gas quality measurement CH4, CO2, H2S and O2.
Special Features
- Project was tendered through the Best Value Procurement methodology with dominant quality score evaluation
General Data
Client
Waterboard Vechtstromen, The Netherlands
Completion
Dec. 2014
Contract value
EURO 1.1 million